Skip to Content

HRV with installation kit

ECM-motor HRV with a complete rigid-duct installation kit, including R8-insulated 6in DIA supply and exhaust for the HRV, an R8-insulated 4in dryer vent and an R8-insulated 6in range hood exhaust. Perfect for owner-builders.

Kit 1 - 2 Bedrooms + 1 Bathroom
Kit 2 - 3 Bedrooms + 2 Bathrooms
4,570.00 $ 4,570.00 $ (Tax excluded)

  • Air exchanger kit option

Make sure you have the right airflow in the right place when you need it. It matters even more in an airtight building. Because after all, it's really about your well-being.

There are

With the Go Passif kit, everything is selected together to work properly right from the start.

According to HVI, the SOLACE is one of the best residential HRVs on the market. Its hexagonal counterflow core recovers up to 80% of the heat from outgoing air — which means less energy loss and tempered fresh air even in the depths of a Québec winter. Its internal recirculation defrost makes it perfectly suited to our climate.

  • Heat recovery: up to 80%
  • MERV 8 filtration included
  • Quiet variable-speed ECM motor
  • Top-mounted connections — ideal for tight spaces
  • EnergyStar and HVI certified

HRV and wall controls:

  • 1 x Greentek Solace 1.5H-EC HRV (made by Fantech)
  • 1 x T4 bathroom timer
  • 1 x STS 2.0 wall control

Cold-side air intake and exhausts (to the outdoors):

  • Metal exhaust hoods with backdraft damper:

    • 1 x 4in for a dryer
    • 1 x 6in for a range hood
    • 1 x 6in for the HRV

  • Metal air intake hoods with vermin screen:

    • 1 x 6in for the HRV fresh air intake

  • R8-insulated flexible ducts with heavy-duty aluminized vapour barrier: 

    • 25ft x 4in DIA
    • 50ft x 6in DIA

Warm-side distribution (into the house):

  • Acoustic flexible ducts to minimize HRV noise: 

    • 2 x Silencers 6in DIA x 30in long

Galvanized steel ducts and fittings for distribution in the house:

  • Round ducts:

    • 75ft x 4in DIA
    • 25ft x 5in DIA
    • 100ft x 6in DIA

  • Oval ducts (perfect for 2x4 partitions):

    • 10ft x 5in DIA Oval

    • 10ft x 6in DIA Oval


  • Adjustable 90deg elbows:

    • 24 x 4in DIA
    • 8 x 4in DIA
    • 20 x 4in DIA

  • Side takeoffs:

    • 2 x 4in DIA
    • 1 x 5in DIA
    •  
  • Airflow balancing dampers:

    • 2 x 4in DIA
    • 1 x 5in DIA
    • 1 x 6in DIA

  • Cap

    • 1 x 6in DIA

  • Wall boxes

    • 1 x 4x10in x 4in DIA
    • 1 x 4x10in x 5in DIA oval*
    • 1 x 4x10in x 6in DIA oval*

Accessories:

  • 2 x Aluminized tapes 2" (MacTac)
  • 1 x Jar of self-drilling metal screws
  • 100ft x Perforated strapping
  • 10ft x 1/2in clear flexible vinyl tubing to drain the HRV
  • 3 x 1/2 in wall clips to secure the tubing to the wall
  • 75ft x 4-conductor thermostat cable
  • 2 x 2.5in electrical junction boxes

Our advisors confirm the right model for your floor area and building type, prepare the complete material list and deliver everything together.




Be sure of the right fresh airflow and a job well done

The more airtight your building, the more comfortable you are. But to stay that way, you absolutely need a reliable supply of fresh air.

Your HRV literally becomes the lungs of your home.

ECM motors = reliable fresh airflow

One key point is choosing a unit with ECM motors. Every duct, elbow and grille adds some restriction along the air distribution path. ECM motors adjust their power to overcome that restriction, making sure the right airflow reaches the end of the line.

A good installation requires the right materials

It would be easy to install everything with flexible ducts. It's fast, inexpensive... and unfortunately very common. But it's neither durable nor reliable. 

Flexible ducts increase pressure losses, reduce actual airflow and collect dust more easily. They're handy for insulated intake and exhaust runs, but the best option is still to slide an insulated sleeve over a rigid duct.

The right approach is to install rigid ducts. They provide:

  • optimal airflow with minimal restriction
  • better system control and balancing
  • easy cleaning over the long term
  • and stable performance year after year

Be sure of a job well done, built to last

That's why we designed a complete, well-thought-out kit to:

  • simplify installation and maximize performance
  • ensure maximum airflow with minimal restriction
  • make sure the job is done right


The right materials do the job right

Rigid ducts provide optimal airflow, minimal restriction and maximum performance.

ECM motors

ECM motors adjust their power to overcome duct system restriction, making sure the right airflow reaches the end of the line.

In the end, it's about your well-being

Be sure of a job well done, built to last. Because at the end of the day, you want good indoor air quality at home for your own well-being.

Contact us

Planning a construction project?

Whether it's a residential or commercial project, send us your plans to get an estimate for your building materials.

20 MB maximum