AEROSANNA VISCONN
Applications
- Pare-air appliqué par voie liquide pour des connexions robustes.
- S'utilise en tant que barrière résistante aux intempéries, solinage pour les appuis de fenêtre en pente, et autres détails.
- VISCONN peut être appliqué au pinceau, au rouleau ou au pistolet sous forme de film liquide et il sèche en formant une membrane uniforme, élastique, étanche à l'air et hygrovariable.
- Convient pour l'intérieur ou l'extérieur
Advantages
- Time-saving airsealing of difficult junction because of airless spray/brush application
- PHI-Certified airbarrier - for interior with vapour-variable properties
- IFT Rosenheim certification as airtight/waterproof joint sealing for insulated window frame rough opening gaps
- For use as WRB on exterior behind rainscreens when shielded from long term UV exposure
- Use appropriate safety protection when using airless sprayer
- Available in two color options: one that is blue when wet and dries black to confirm drying, one that is white when both wet or dry
Substrates
- Time-saving airsealing of difficult junction because of airless spray/brush application
- PHI-Certified airbarrier - for interior with vapour-variable properties
- IFT Rosenheim certification as airtight/waterproof joint sealing for insulated window frame rough opening gaps
- For use as WRB on exterior behind rainscreens when shielded from long term UV exposure
- Use appropriate safety protection when using airless sprayer
- Available in two color options: one that is blue when wet and dries black to confirm drying, one that is white when both wet or dry
Properties
- Material: Aqueous acrylic dispersion
- Passed ASTM E331/ IBC - 1403.2 (300PA for 2 hours) for WRB code compliance
- Temperature Resistance: -40 F to +176 F
- Perm Rating: 0.5 perms (6.11m ±0.6 m) at 11 mils (0.3 mm) thickness EN 1931
- Vapour Variability ISO 12572: 0.33 to 25 perms (Sd: 0.13 – 10.00 m)
- Recommended airless sprayers: Graco Hi-Boy 390, 395, 490, or 495 - see Reference Downloads for guide
- UV/weather Resistance: 3 months of exposure
- NBC 2020- 9.36.2.9 Air Barrier Systems Passed air leakage <0.02 L/(s*m2 @75 Pa (ASTM E2357)
- Low VOC per SCAQMD limits
- LEEDV4 passed CDPH v1.2 for Private Office and School Classroom (PO and SC)
- Living Building Challenge RED list free
AVERTISSEMENT DE GEL HIVERNAL
Maintenir au-dessus du point de congélation
VISCONN doit être maintenu au-dessus du point de congélation à tout moment, y compris à son arrivée sur le chantier avant l'application. Les camions de livraison laissent souvent les colis à l'extérieur sans demander de signature. Tenez compte de l'arrivée estimée de votre livraison et évitez de la laisser dehors dans des conditions de gel. Vérifiez le produit immédiatement après sa livraison pour vous assurer que rien n'a gelé.